Showing 10–18 of 39 results

View
Filters:
  • ,

    DATAQ Model DI-4108-U

    DATAQ    Model DI-4108-U
    USB DAQ and Data Logger, 12 to 16-bit resolution, 160,000 S/s Throughput, Records to USB flash drive
    Includes a DI-4108 instrument, a 6-foot USB cable, a screwdriver for signal connections, and a USB flash drive with WinDaq/Lite software (downloadable at run.dataq.com) and an NIST-traceable calibration certificate (.pdf)

    Provided with WinDaq/Lite Software, which records up to four channels at any sampling rate.  WinDaq/Unlock code required per device for data synchronization in WinDaq.

    Stand-alone capability to USB thumb drive (Unlock Code required to record all channels to USB thumb drive – See Accessories)

    Up to 160,000 Hz Sample Throughput Rate using WinDaq Acquisition software

    Up to 160,000 Hz Sample Throughput Rate in stand-alone mode using high speed microSD card

    12 to 16-bit analog-to-digital resolution (Calculate Resolution)

    Programmable ranges: ±200, ±500 mV, ±1, ±2, ±5, ±10 V full scale

    Eight armored analog differential inputs*

    Up to 120 V rms without damage

  • ,

    DATAQ Model DI-808

    DATAQ Model DI-808
    Eight-channel Web-based Voltage, Thermocouple, and Pulse Data Logger
    Includes a DI-808 instrument, a screwdriver for signal connections, a power supply, and an NIST-traceable calibration certificate

    No software to install

    Intelligent data logger with built-in web server works with with any device using a modern web browser

    Stores data locally to internal flash memory or a USB thumb drive and/or remotely to any accessible server or email address

    Allows remote real time display and configuration

    Eight differential and isolated analog input channels programmable as voltage or thermocouple per channel measuring ±10mV, ±25mV, ±50mV, ±100mV, ±250mV, ±500mV, ±1V, ±2.5V, ±5V, ±10V, ±25V, or ±50V; or Thermocouple types J, K, T, B, R, S, E, or N

     

  • ,

    1750

    Recognized as the industry's fastest precision microohmmeter, the model 1750 has become the #1 choice in manufacturing environments. Fuse manufacturers use it for nondestructive tests where the unmatched precision increases the process yield to the point where the 1750 pays for itself in weeks. The vast majority of resistors less than 1 Ohm are tested and sorted to accuracy better than 0.1% by the 1750. Automotive suppliers use it to consistently meet stringent quality requirements of welds, bonds and electrical connection in sub-assemblies. Aircraft manufacturers employ the 1750 to measure wiring harnesses and RF shields for connection integrity. The capability of the 1750 enables the accurate real time measurement of electro-plating thickness and conductive coatings on housings and shields.

  • ,

    9334A

    The 9334A SERIES of DC Air Based Resistance Standards are designed for high accuracy resistance calibration in air.

  • ,

    SAS-17E & SAS-36E

    SAS-E is a high performance, highly manageable and reliable solution for distributing time and frequency signals for satcom, digital TV or audio broadcast, microwave links, satellite ground stations applications.

    The Epsilon™ Switch and Amplifier System (SAS-E) provides a cost effective way to extend distribution of time and frequency signals (pulse, low phase noise frequency signal, Time of Day), as a signal amplifier. Thanks to analog amplification, SAS-E adds very little phase noise to the input frequency and ensures high RF isolation. It is therefore suitable for reference frequency distribution towards transmitters, up-converters, micro-wave links. Pulse regeneration is transparent to pulse duration and period: SAS-E is therefore suitable for distribution of any pulse encoded signal like 1 pps, DCLS IRIG, etc

     

  • ,

    2340/2350

    The Model 2340 High Voltage Amplifier expands the amplitude range of any standard function, pulse or waveform generator to 400 Vp-p. There is also a special high impedance input option for DAC boards. The DC coupled design enables combined DC and AC wave forms for greatest flexibility in test applications.  The response and gain are calibrated for a faithful reproduction of the test signal.

    The output current is rated at 40 mA continuous with a 0.2 Ω output impedance. Each channel has an independent, buffered, voltage monitor output for applications that require a low-level representation of the output signal. The buffers produce a reduction of 200:1 for 50 Ω inputs and 100:1 for 1 MΩ and above inputs. A current limiting function senses the current in either direction providing maximum protection to the amplifier during operation.

  • , , , , ,

    DL350

    The DL350 ScopeCorder is a portable instrument featuring the deep measurement and recording capabilities you need in the lab in a compact instrument you can take into the field. A ScopeCorder combines the transient signal capturing capabilities of an oscilloscope with the long-term datalogging capabilities of a data recorder. For “quick and easy” troubleshooting or sophisticated mixed-signal datalogging, the DL350 is a portable, powerful, and useable engineering tool that makes complete measurements completely portable.

  • , , ,

    PXI-9846D 4-CH, 40MS/S, 16-BIT PXI-H DIGITIZER MODULE

    • 4-CH, 40MS/s, 16-bit digitizer
    • 512 MB deep on-board memory for recording waveforms for extended periods
    • Software selectable 50Ω or 1 MΩ input impedance
    • ±0.2V and ±1V input ranges
    • External clock support
    • Extensive analog and digital triggering
    • Fully auto-calibration