Arbitrary Output DC Power Supplies, Battery Analyzers, DC Power Supplies, Power Sources & Measurement, Rechargeable Batteries, Semiconductor Characterization Equipment, Semiconductor Source Measure Units, Test & Measurement
GS820 MULTI CHANNEL SOURCE MEASURE UNIT
The GS820 is equipped with two analog channels with each channel consisting of a constant voltage source VS, a constant current source IS, a voltmeter VM, and an ammeter IM. The two source measure channels are isolated.
- DC voltage/current reference, pulse voltage/current source
- V-I curve trace, semiconductor parametric test
- Programmable arbitrary waveform generation
- Electric load, resistance measurement
- Production test
-
Arbitrary Output DC Power Supplies, Battery Analyzers, DC Power Supplies, Power Sources & Measurement, Rechargeable Batteries, Semiconductor Characterization Equipment, Semiconductor Source Measure Units, Test & Measurement
GS610 SOURCE MEASURE UNIT
The GS610 is a highly accurate and highly functional programmable voltage/current source that incorporates voltage/current generation and measurement functions. The maximum output voltage and current are 110 V and 3.2 A, respectively. Evaluation of over a wide range of basic electrical characteristics is possible, because the GS610 can operate as a current source or a current sink.
-
DC Power Supplies, Power Sources & Measurement, Sensitive Measurements, Test & Measurement, Voltage/Current Sources and Measurement
GS200 DC VOLTAGE / CURRENT SOURCE
The GS200 is a low voltage/current DC source with high accuracy, high stability, and high resolution. With its excellent traceability, stability, and 5 1/2-digit resolution, the GS200 generates extremely low-noise DC voltage and current signals that are required for many applications. Additionally, the optional monitoring feature turns the GS200 into a voltage and current measuring instrument.
General Specifications - Voltage source up to ±32 V and current source up to ±200 mA
- 51/2-digit, 120000-count output resolution
- Voltage and current simple monitoring feature (optional)
- Programmable output up to 10,000 points
- Built-in USB mass storage device
- Channel expansion through synchronous operation
-
ATE Systems, LXIbus Instruments, Switching Systems, Test & Measurement
EX1200-6101 10 CHANNEL SP4T, 1.3 GHZ COAXIAL SWITCH, 50 Ω
- Highest density RF switches and matrices
- 50 W maximum switching power
- Can be mixed and matched to create application specific configurations
- Ideal for general purpose RF switching with high signal fidelity and total system bandwidths > 1 GHz
- No unterminated stub effects
- Excellent crosstalk and isolation specifications
-
ATE Systems, LXIbus Instruments, Switching Systems, Test & Measurement
EX1200-6216 DUAL (1X16), 1 GHZ RF MULTIPLEXER, 50 Ω
- Highest density RF switches and matrices
- 50 W maximum switching power
- Suitable for switching RF signals to/from high bandwidth measurement devices such as oscilloscopes and function generators
- Can be mixed and matched to create application specific configurations
- Coax shields are isolated from system ground to minimize ground loop effects
- No unterminated stub effects
-
ATE Systems, LXIbus Instruments, Switching Systems, Test & Measurement
EX1200-2001 20 CHANNEL 16 AMP FORM A (SPST) SWITCH
- Large switching capacity in a small footprint
- Switch up to 16 A current – highest in its class
- High breakdown voltage (1,000 V RMS between open contacts)
- Ideal for switching AC or DC power supplies and current sources
- Fail-safe interrupt inputs that can detect a fault condition automatically open up relays to their default state
-
ATE Systems, Digital Multimeters, LXIbus Instruments, Test & Measurement
EX1200-2365 FULL FEATURED, TIGHTLY INTEGRATED 6.5 DIGIT DMM FOR 3U EX1200 MAINFRAME
- Modular 6.5 digit DMM for 3U EX1200 mainframes (EX1208A)
- Tightly integrated into mainframe, allowing high-speed, synchronized scanning measurements without the need for external cabling.
- Input can be routed directly to the DMM or through an internal analog bus on the backplane
- Superfast scanning with no processor intervention required
- Scanning configuration can be saved in the DMM’s non-volatile memory allowing quick recall of saved states
- Integrating ADC with adjustable integration time depending on the level of accuracy required
- “True RMS” AC readings
- Supports frequency and temperature (thermocouple, RTD and thermistor) measurements
- PHONE : 949-955-1894
- Email :
-
ATE Systems, Digital Multimeters, LXIbus Instruments, Test & Measurement
EX1200-2165 FULL FEATURED, TIGHTLY INTEGRATED 6.5 DIGIT DMM FOR 1U EX1200 MAINFRAMES
- Modular 6.5 digit DMM for 1U EX1200 mainframes (EX1206A and EX1202A)
- Tightly integrated into mainframes, allowing high-speed, synchronized scanning measurements without the need for external cabling.
- Input can be routed directly to the DMM or through an internal analog bus on the backplane
- Superfast scanning with no processor intervention required
- Scanning configuration can be saved in the DMM’s non-volatile memory allowing quick recall of saved states
- Integrating ADC for with adjustable integration time depending on the level of accuracy required
- “True RMS” AC readings
- Supports frequency and temperature (thermocouple, RTD and thermistor) measurements
-
ATE Systems, LXIbus Instruments, Switching Systems, Test & Measurement
EX1200-2008H 30-CHANNEL 3 (1 X 10) HIGH-VOLTAGE MULTIPLEXER
- High-density, high-voltage multiplexer/scanner (1×180 in 1U size)
- Ideal for hipot, cable breakdown, source measure unit and power supply switching
- Extensive signal shielding employed on-board for excellent signal fidelity
- Break-before-make (BBM) and make-before-break (MBB) accomplished in hardware, considerably improving scanning time
- Fail-safe interrupts can detect fault conditions and automatically open up relays to a default state
-
ATE Systems, LXIbus Instruments, Switching Systems, Test & Measurement
EX1200-2007A 48-CHANNEL 1000V MULTIPLEXER
- Highest density module in its class for ability to switch signals up to 1000 V DC (up to 144 two-wire channels in 1U footprint)
- Built-in configuration relays expand the individual building blocks
- Ideal for hipot, cable breakdown, source measure unit and power supply switching
- Extensive signal shielding employed on-board for excellent signal fidelity
- Fail-safe interrupts can detect fault conditions and automatically open up relays to a default state
-
ATE Systems, Data Acquisition Systems, LXIbus Instruments, Test & Measurement
EX1202/EX1262 2-SLOT, HALF-RACK LXI SWITCHING AND DATA ACQUISITION MAINFRAMES
- ½ rack, 1U, 2-slot ,mainframe
- Internal 5-wire bus routes directly to optional full featured 6.5 digit DMM
- Modules plug in from the front – minimizes system wiring
- LXI communication interface eliminates platform obsolescence and support cost concern
- Tightly synchronized measurements in a distributed architecture using IEEE-1588
- 8-line LXI wired trigger bus – precision hardware handshaking
- Scalable from table-top to production system with ½ rack 1U, 1U, and 3U options
- Low cost-per-channel across a wide range of channel count
-
ATE Systems, Data Acquisition Systems, LXIbus Instruments, Switching Systems, Test & Measurement
EX1206A/EX1266 6-SLOT, 1U LXI SWITCHING AND DATA ACQUISITION MAINFRAMES
- 1U, 6-slot ,mainframe
- Internal 5-wire bus routes directly to optional full featured 6.5 digit DMM
- Modules plug in from the front – minimizes system wiring
- LXI communication interface eliminates platform obsolescence and support cost concern
- Tightly synchronized measurements in a distributed architecture using IEEE-1588
- 8-line LXI wired trigger bus – precision hardware handshaking
- Scalable from table-top to production system with ½ rack 1U, 1U, and 3U options
- Low cost-per-channel across a wide range of channel count
-
ATE Systems, Test & Measurement, VXIbus Instruments
VM3616A 16-CHANNEL, 16-BIT DAC/WAVEFORM GENERATOR
- 16 independent 16-bit D/A converters per instrument for high speed signal generation
- Up to 48 D/A converters per VXIbus C-Size slot
- ±20V and ±10V output ranges
- Up to 100 kSa/s Arbitrary Waveform Generation with internal programmable clock
- FIFO mode allows high-speed uninterrupted data output
- Data storage and scan lists speed testing
- Extensive triggering capability
- SCPI compatible
- VXIplu&play drivers
-
Test & Measurement, Timers/Counters/Analyzers, WiFi Solutions
WLn-LINK-OEM
WLn-LINK-OEM embedded module is a 2.4 / 5 GHz IEEE 802.1a/b/g/n solution designed to quickly and easily add wireless LAN to a wide range of wired Ethernet OEM products.
-
Test & Measurement, Timers/Counters/Analyzers, WiFi Solutions
RailBox Rugged & outdoor
RailBox is a rugged device designed for railway and light rail applications. It can be mounted in trains, subways, trams or in any equipment that requires robustness and mobility.
RailBox can be implemented by system integrators and rail vehicle manufacturers who are seeking to establish high availability for:
- uninterrupted train-to-trackside communications (CBTC, CCTV, VoIP, preventive maintenance, PIS…)
- carriage coupling (to support any train composition change and provide a redundant & reliable onboard network)
- reliable onboard vehicle network (WiFi onboard, train announcements, infotainment…)
The device relies on the multi-streams MIMO technology that contributes to an expanded coverage, higher data throughput and increased radio link reliability.
Furthermore it combines an optional LTE mobile broadband router plus a GPS allowing using the device as a mobile hotspot in transportation applications (coming soon).
It fulfills the most severe requirements in terms of operating environment: from -25°C to +70°C (extended :-40°C to +85°C), shock and vibration proof, protection against dust and water projections (IP66).
-
Calibration Instruments, Precision Instrumentation, Reference Time & Frequency, Test & Measurement, Timers/Counters/Analyzers
CNT-91 Frequency Timer/Counter/Analyzer/Calibrator Details
The CNT-90 Frequency Timer/Counter/Analyzer is excellent for measurement, analysis and calibration of frequency, time, or phase. In production test systems, R&D, the calibration lab, or in the field; the CNT-90 timer/counter/analyzer outperforms many existing counters on the market.
Fast Speed and High Resolution
The CNT-90 is a high-performance frequency counter with a fast measurement speed to 250,000 measurements/sec, with a memory depth of 750k to internal memory; high resolution of 100 ps single shot (time); and 12 digits/sec resolution (frequency). The CNT-90 offers ease-of-use, a multi-mode graphic/numeric display, and improved control over measurements, at a very competitive price.
-
Reference Time & Frequency, Timers/Counters/Analyzers
VersaSync Rugged GPS Time & Frequency Reference
Backed by more than four decades of Spectracom’s timing solutions expertise, VersaSync includes all the timing functionality required in modern, network-centric applications:
- NTP/PTP precise time transfer over Ethernet, including security protocols that prevent network vulnerabilities
- Low phase noise 10 MHz frequency distribution
- Configurable pulse signals, including IRIG or HaveQuick timecodes
- Serial link Time Of Day (ToD) messages
A Perfect Fit for GPS-Denied Environments
VersaSync accommodates an OCXO or a CSAC oscillator, allowing the unit to maintain frequency and time accuracy for long periods of GPS/GNSS outage. In addition, it can be re-synchronized by an external reference.
-
Distribution Time & Frequency, Reference Time & Frequency, Timers/Counters/Analyzers
SecureSync PTP Grandmaster
Equipped with the latest and most innovative 10/100/1000 Base-T Gigabit PTP Option Card on the market, the SecureSync High-Speed PTP Grandmaster Clock boasts industry-leading packet throughput and data processing power. The installment of an optional slave-ready 10/100 Mb PTP Option Card creates a powerful master-slave combination to satisfy even the most rigorous timing requirements.
Standard RF and fiber optic interfaces via SFP modules provide the ability to select between either of the two media relative to your specific needs, greatly reducing the effects of distance limitations within your system architecture.