-
General Laboratory Instruments, LCR METERS, Test & Measurement
ZM serie
nF ZM series LCR meters cover a wide frequency range, from the low-frequency region of 1 mHz up to 5.5 MHz. Supports a wide range of applications, from materials research to component production lines, by means of high-speed, low measurement fluctuation
-
Frequency Response Analyzer, General Laboratory Instruments, Test & Measurement
Model FRA51615
The FRA51615 is suitable to measure frequency response for many industries from electronic circuits, electronic components, and materials to mechatronics and electrochemical applications. Equipped with the performance and functionality to support many industries, FRA51615 provides highly reproducible measurement data and more efficient testing operations.
The FRA51615 is the newest FRA developed to meet the needs and desires of our customers, and to provide the best user-friendliness, down to the smallest detail, featuring 10μHz to 2MHz, Gain accuracy ±0.01dB, Phase accuracy ±0.06°
-
General Laboratory Instruments, Lock-in Amplifiers, Test & Measurement
Model LI5600
Lock-in Amplifiers that measure extremely small alternating signals hidden deep within noise, are used in a wide range of advanced research fields, including scanning probe microscopes, terahertz spectroscopy and spintronics.
NF's newest lock-in amplifier LI5600 series is 2-phase, 2-frequency digital lock-in amplifier that delivers a high level of stability with post-phase detection digital signal processing. The series covers all areas of key functionality required for increasing reliability when measuring very small signals, such as an outstanding dynamic reserve up to 100 dB, update rates up to approximately 1.5 M samples/s (LI5660/LI5655), and smooth, high-speed 16-bit amplitude resolution output response.
-
General Laboratory Instruments, Signal Generators, Function and Arbitrary, Test & Measurement
TOE 7741
TOELLNER Model TOE 7741 Function Generator
- Frequency range 1 mHz to 100 kHz
- High output power > 63 W into 8 Ohm
- Max. output amplitude 45 Vpp
- Output with feedback voltage protection
- Frequency counter up to 30 MHz
-
General Laboratory Instruments, Signal Generators, Function and Arbitrary, Test & Measurement
TOE 7761
TOELLNER Model TOE 7761 Arbitrary Function Generator
- 1 μHz to 40 MHz sine and square waveforms
- Output amplitude up to 20 Vss
- 80 MS/s sampling rate with arbitrary waveforms with 14 bit resolution and up to 1 000 000 sampling points
- Flash memory for 1 000 000 sampling points
- Many standard waveforms assist in creating arbitrary waveforms
- Various modulation and sweep options
- 50 instrument configurations can be stored
- Remote control via USB-1), GPIB- and RS-232 interface
-
Amplifier Wideband, General Laboratory Instruments, Test & Measurement
TOE 7607
TOELLNER Model TOE 7607 Broadband Amplifier
- High output voltage of up to 40 Vpp into 50 Ohm
- Wide frequency range from DC to 5 MHz
- Gain of up to 26 dB
- Small distortion factor
-
General Laboratory Instruments, Sensitive Measurements, Test & Measurement
TEGAM Model 1740
TEGAM Model 1740 High Speed Microohmmeter, including GPIB & RS-232
Basic Accuracy: 0.02%
Measurement Speed: 10 ms
Range: 20 mΩ to 20 MΩ
Resolution: 1 µΩ
Programmable reference currents
Kelvin Klips, Spade Lugs or Kelvin Probes available
Easy to operate and easy to integrate
1-year warranty on this Microohmmeter
Made in USA -
General Laboratory Instruments, LCR METERS, Test & Measurement
TEGAM Model 253 LCR
TEGAM Model 253 LCR Meter Auto-ranging LCR Meter, 1 kHz, Battery Powered
Basic Accuracy: 0.25%
Measurement Speed: 250 ms
Test Frequency: 1 kHz
Automatic L, C, R, G and D measurements
Auto Ranging
Shielded Kelvin Connections
Rechargeable Battery Power Pack
Rear Panel External Bias Terminals
Calibration Certificate Included
1-year warranty
Made in USA -
Data Acquisition Systems, General Laboratory Instruments
DATAQ DI-4718B
DATAQ DI-4718B Data Acquisition and Data Logger Products
Measures temperature, pressure, flow, current, voltage, and more using isolated 8B amplifiers. View the DI-8B amplifier selection guideLow-Cost, Portable, USB or Ethernet Data Logger
Eight DI-8B signal-conditioned analog inputs. Expandable with ChannelStretch™ (Unlock code required for each instrument)
Stand-alone data logger option allows in-the-field measurements to be saved to flash memory (unlock code required for each instrument to record all channels to flash memory)
Up to 16-bit analog to digital conversion
-
Data Acquisition Systems, General Laboratory Instruments
DATAQ Model DI-4108-U
DATAQ Model DI-4108-U
USB DAQ and Data Logger, 12 to 16-bit resolution, 160,000 S/s Throughput, Records to USB flash drive
Includes a DI-4108 instrument, a 6-foot USB cable, a screwdriver for signal connections, and a USB flash drive with WinDaq/Lite software (downloadable at run.dataq.com) and an NIST-traceable calibration certificate (.pdf)Provided with WinDaq/Lite Software, which records up to four channels at any sampling rate. WinDaq/Unlock code required per device for data synchronization in WinDaq.
Stand-alone capability to USB thumb drive (Unlock Code required to record all channels to USB thumb drive – See Accessories)
Up to 160,000 Hz Sample Throughput Rate using WinDaq Acquisition software
Up to 160,000 Hz Sample Throughput Rate in stand-alone mode using high speed microSD card
12 to 16-bit analog-to-digital resolution (Calculate Resolution)
Programmable ranges: ±200, ±500 mV, ±1, ±2, ±5, ±10 V full scale
Eight armored analog differential inputs*
Up to 120 V rms without damage
-
Data Acquisition Systems, General Laboratory Instruments
DATAQ Model DI-808
DATAQ Model DI-808
Eight-channel Web-based Voltage, Thermocouple, and Pulse Data Logger
Includes a DI-808 instrument, a screwdriver for signal connections, a power supply, and an NIST-traceable calibration certificateNo software to install
Intelligent data logger with built-in web server works with with any device using a modern web browser
Stores data locally to internal flash memory or a USB thumb drive and/or remotely to any accessible server or email address
Allows remote real time display and configuration
Eight differential and isolated analog input channels programmable as voltage or thermocouple per channel measuring ±10mV, ±25mV, ±50mV, ±100mV, ±250mV, ±500mV, ±1V, ±2.5V, ±5V, ±10V, ±25V, or ±50V; or Thermocouple types J, K, T, B, R, S, E, or N
-
General Laboratory Instruments, Sensitive Measurements
1750
Recognized as the industry's fastest precision microohmmeter, the model 1750 has become the #1 choice in manufacturing environments. Fuse manufacturers use it for nondestructive tests where the unmatched precision increases the process yield to the point where the 1750 pays for itself in weeks. The vast majority of resistors less than 1 Ohm are tested and sorted to accuracy better than 0.1% by the 1750. Automotive suppliers use it to consistently meet stringent quality requirements of welds, bonds and electrical connection in sub-assemblies. Aircraft manufacturers employ the 1750 to measure wiring harnesses and RF shields for connection integrity. The capability of the 1750 enables the accurate real time measurement of electro-plating thickness and conductive coatings on housings and shields.
-
General Laboratory Instruments, Resistance Standards
9334A
The 9334A SERIES of DC Air Based Resistance Standards are designed for high accuracy resistance calibration in air.
-
Distribution Amplifiers, General Laboratory Instruments
SAS-17E & SAS-36E
SAS-E is a high performance, highly manageable and reliable solution for distributing time and frequency signals for satcom, digital TV or audio broadcast, microwave links, satellite ground stations applications.
The Epsilon™ Switch and Amplifier System (SAS-E) provides a cost effective way to extend distribution of time and frequency signals (pulse, low phase noise frequency signal, Time of Day), as a signal amplifier. Thanks to analog amplification, SAS-E adds very little phase noise to the input frequency and ensures high RF isolation. It is therefore suitable for reference frequency distribution towards transmitters, up-converters, micro-wave links. Pulse regeneration is transparent to pulse duration and period: SAS-E is therefore suitable for distribution of any pulse encoded signal like 1 pps, DCLS IRIG, etc
-
Amplifier Wideband, General Laboratory Instruments
2340/2350
The Model 2340 High Voltage Amplifier expands the amplitude range of any standard function, pulse or waveform generator to 400 Vp-p. There is also a special high impedance input option for DAC boards. The DC coupled design enables combined DC and AC wave forms for greatest flexibility in test applications. The response and gain are calibrated for a faithful reproduction of the test signal.
The output current is rated at 40 mA continuous with a 0.2 Ω output impedance. Each channel has an independent, buffered, voltage monitor output for applications that require a low-level representation of the output signal. The buffers produce a reduction of 200:1 for 50 Ω inputs and 100:1 for 1 MΩ and above inputs. A current limiting function senses the current in either direction providing maximum protection to the amplifier during operation.
-
DATA ACQUISITION, Data Acquisition Systems, General Laboratory Instruments, OSCILLOSCOPES, Osciloscopes, Test & Measurement
DL350
The DL350 ScopeCorder is a portable instrument featuring the deep measurement and recording capabilities you need in the lab in a compact instrument you can take into the field. A ScopeCorder combines the transient signal capturing capabilities of an oscilloscope with the long-term datalogging capabilities of a data recorder. For “quick and easy” troubleshooting or sophisticated mixed-signal datalogging, the DL350 is a portable, powerful, and useable engineering tool that makes complete measurements completely portable.
-
Data Acquisition Systems, General Laboratory Instruments
SIRIUS R8D rack display solution
8 to 32 analog inputs
-
ATE Systems, Data Acquisition Systems, PXIbus Instruments, Test & Measurement
PXI-9846D 4-CH, 40MS/S, 16-BIT PXI-H DIGITIZER MODULE
- 4-CH, 40MS/s, 16-bit digitizer
- 512 MB deep on-board memory for recording waveforms for extended periods
- Software selectable 50Ω or 1 MΩ input impedance
- ±0.2V and ±1V input ranges
- External clock support
- Extensive analog and digital triggering
- Fully auto-calibration
-
ATE Systems, Data Acquisition Systems, PXIbus Instruments, Test & Measurement
PXI-2204 64-CH, 3MS/S 12-BIT MULTI-FUNCTION PXI-H MODULE
- 64-CH single ended/32-CH differential, 12-bit scanning analog inputs
- Up to 3 MSa/s sampling rate
- Multiple programmable ranges from 0.05V (min) to 10V with unipolar or bipolar modes
- 2-CH, 12-bit multiplying analog outputs with waveform generation
- 24-CH TTL Digital I/O
- 2-CH 16-bit general purpose timer/counter
- Analog and digital triggering
- Auto-calibration
-
ATE Systems, Data Acquisition Systems, PXIbus Instruments, Test & Measurement
PXI-2010 4-CH, 2MS/S SIMULTANEOUS A/D MULTI-FUNCTION PXI-H MODULE
- 4-CH differential, 14-bit, 2 MS/s analog inputs
- Four programmable ranges 1.25V to 10V with unipolar or bipolar modes
- 2-CH, 12-bit multiplying analog outputs with waveform generation
- 24-CH TTL Digital I/O
- 2-CH 16-bit general purpose timer/counter
- Analog and digital triggering
- Auto-calibration
-
ATE Systems, Data Acquisition Systems, PXIbus Instruments, Test & Measurement
PXI-2005 4-CH, 500KS/S SIMULTANEOUS A/D MULTI-FUNCTION PXI-H MODULE
- 4-CH differential, 16-bit, 500 kS/s analog inputs
- Four programmable ranges 1.25V to 10V with unipolar or bipolar modes
- 2-CH, 12-bit multiplying analog outputs with waveform generation
- 24-CH TTL Digital I/O
- 2-CH 16-bit general purpose timer/counter
- Analog and digital triggering
- Auto-calibration
-
ATE Systems, Data Acquisition Systems, Physical Measurements, PXIbus Instruments, RPM and Speed, Sound and Vibration, Test & Measurement, Torque
PMX04 PORTABLE 4-SLOT 3U PXI EXPRESS ‘TABLET’ WITH INTEGRATED DISPLAY
- 4-slot PXI Express tablet test and computing system
- Hybrid mixed PXI/PXIe slot chassis
- Multipoint capacitive touch screen LCD
- Durable construction for industrial systems
- Integrated 14” 1366 x 768 LCD Display
- Internal Intel Core i7 Quad Core Processor, 1.7 Ghz
- QM67 PCH Chipset, equipped with 4GB DDR3 DRAM
- Internal 256GB HDD Drive standard with SATA 3.0 interface
- Wide range peripheral interface
-
ATE Systems, Data Acquisition Systems, Physical Measurements, PXIbus Instruments, RPM and Speed, Sound and Vibration, Test & Measurement, Torque
EMX-4380 625 KSA/S, 4 CH, 24-BIT SMART PXIE DSA INSTRUMENT, CHARGE, IEPE AND VOLTAGE
- First integrated data acquisition instrument to support IEPE, charge, and voltage inputs
- 625 kSa/s/channel, 24-Bit ADC, 4-Channel
- Flexible analog and user defined digital filter combinations
- True differential inputs with 25 V Isolation
- Exceptional noise immunity
- Highest quality instrumentation grade ADC’s outperform commonly used audio grade ADC’s
- Fully programmable excitation (2 mA to 20 mA)
- Deterministic channel-to-channel, card-to-card, and chassis-to-chassis phase response
-
ATE Systems, Data Acquisition Systems, Physical Measurements, PXIbus Instruments, RPM and Speed, Sound and Vibration, Test & Measurement, Torque
EMX-4350 625 KSA/S, 4-CH, 24-BIT SMART PXIE DSA INSTRUMENT, IEPE AND VOLTAGE
- 625 kSa/s/channel, 24-Bit ADC, 4-Channel
- True Differential, IEPE or Voltage, AD/DC Inputs
- Flexible analog and user defined digital filter combinations
- Best-in-class noise immunity
- Highest quality instrumentation grade ADC’s outperform commonly used audio grade ADC’s
- Best-in-class -125 dB SFDR
- Unparalleled fully programmable excitation (2 mA to 20 mA)
- Deterministic channel-to-channel, card-to-card, and chassis-to-chassis phase response
-
ATE Systems, Data Acquisition Systems, Physical Measurements, PXIbus Instruments, Sound and Vibration, Test & Measurement
EMX-4250 16-CHANNEL, 204.8 KSA/S SMART PXIE DSA DIGITIZER
- 204.8 kSa/s/channel, 24-Bit ADC’s, 16-Channel
- Differential inputs deliver superior common mode performance
- Flexible analog and user defined digital filter combinations
- -105 dB SFDR
- Seven auto-ranging input ranges from 100 mV to 10 V
- Deterministic channel-to-channel, card-to-card, and chassis-to-chassis phase response
-
ATE Systems, Data Acquisition Systems, Physical Measurements, PXIbus Instruments, Sound and Vibration, Test & Measurement
EMX-4251 8-CHANNEL, 204.8 KSA/S SMART PXIE DSA DIGITIZER
- 204.8 kSa/s/channel, 24-Bit ADC’s, 8-Channel
- Differential inputs deliver superior common mode performance
- Flexible analog and user defined digital filter combinations
- -105 dB SFDR
- Seven auto-ranging input ranges from 100 mV to 10 V
- Deterministic channel-to-channel, card-to-card, and chassis-to-chassis phase response
-
DC Power Supplies, Power Sources & Measurement, Sensitive Measurements, Test & Measurement, Voltage/Current Sources and Measurement
GS200 DC VOLTAGE / CURRENT SOURCE
The GS200 is a low voltage/current DC source with high accuracy, high stability, and high resolution. With its excellent traceability, stability, and 5 1/2-digit resolution, the GS200 generates extremely low-noise DC voltage and current signals that are required for many applications. Additionally, the optional monitoring feature turns the GS200 into a voltage and current measuring instrument.
General Specifications - Voltage source up to ±32 V and current source up to ±200 mA
- 51/2-digit, 120000-count output resolution
- Voltage and current simple monitoring feature (optional)
- Programmable output up to 10,000 points
- Built-in USB mass storage device
- Channel expansion through synchronous operation
